BS 6724 LSZH Sheath 0.6/1kv LV Power Swa Armored Cable

Model NO.: SWA cable
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, SGS
Model: Armor Cable
Brand: Hongda
Armoured: Steel Wire or Steel Tape
Trademark: Hongda Cable
Transport Package: Steel & Wooden Drum
Specification: 1.5mm2 to 400mm2
Origin: China
HS Code: 8544492100
Model NO.: SWA cable
Wire Core Material: Bare Copper Wire
Certification: ISO, CCC, SGS
Model: Armor Cable
Brand: Hongda
Armoured: Steel Wire or Steel Tape
Trademark: Hongda Cable
Transport Package: Steel & Wooden Drum
Specification: 1.5mm2 to 400mm2
Origin: China
HS Code: 8544492100
BS 6724 SWA Armoured LSZH Sheath 0.6/1kV LV Power Armour Cable

1. Overview
Low Voltage Power Cables, Aluminum and Copper conductors of voltage range:0.6/1.0 kV.

2. Cable Types
Copper Conductor Cables
Aluminium Conductor Cables
Thermoplastic/ PVC Insulated Cables
Thermoset/XLPE Insulated Cables
Armoured/ Non - Armoured Cables
Single core cables up to and including 1000 mm2
2 core cables up to and including 95 mm2
3, 4 core & 4 core with reduced neutral cables up to and including 500 mm2

3. Applicable Standards
IEC 60502 (Part 1)"PVC/ XLPE insulated cables" single core /multi-core BS 5467 for XLPE insulated Armoured cables
BS 7889 for XLPE insulated single core unarmoured cables
BS 6724 LSZH Sheath 0.6/1kv LV Power Swa Armored Cable

4. Cables Include:
4.1 BS 6724 SWA LSZH 0.6/1kV Cable
4.1.1 Cable construction
Conductor Class 2 stranded copper conductor according to BS EN 60228
Insulation XLPE (Cross-Linked Polyethylene)
Bedding LSZH (Low Smoke Zero Halogen) Type LTS1 according to BS 7655
Armour SWA (Steel Wire Armour)
Sheath LSZH (Low Smoke Zero Halogen) Type LTS1 according to BS 7655

4.1.2 Electrical Characteristics
Dimensions - BS6724 XLPE/LSZH/SWA/LSZH (Copper)
No. of Cores Nominal Cross Sectional Area Nominal Thickness of Insulation Nominal Overall Diameter mm Nominal Weight
mm² mm Under Armour Overall kg/km
2 1.5 0.6 7.3 12.1 302
2 2.5 0.7 8.5 13.6 346
2 4 0.7 9.4 14.7 410
2 6 0.7 10.5 15.9 499
2 10 0.7 12.3 18 648
2 16 0.7 14.3 20.4 978
2 25 0.9 14.7 20.4 1290
2 35 0.9 16.8 23.3 1500
2 50 1 19 25.8 1890
2 70 1.1 22 29 2450
2 95 1.1 25.1 33.1 3300
2 120 1.2 27.9 36.1 4020
2 150 1.4 30.9 39.3 4750
3 1,5 0.6 7.8 12.6 330
3 2.5 0.7 9.2 14.1 390
3 4 0.7 10 15.3 464
3 6 0.7 11.2 16.6 568
3 10 0.7 13.1 19.5 866
3 16 0.7 15.3 21.6 1152
3 25 0.9 18.9 23.6 1800
3 35 0.9 21.3 25.7 2230
3 50 1 21.7 28.5 2490
3 70 1.1 25.2 32.2 3290
3 95 1.1 28.8 37 4440
3 120 1.2 32 40.4 5470
3 150 1.4 35.9 45.5 6930
3 185 1.6 40 49.8 8350
3 240 1.7 44.9 55.1 10400
3 300 1.8 49.8 60.2 12600
3 400 2 55.8 66.6 14600
4 1.5 0.6 8.5 13.3 365
4 2.5 0.7 9.9 15 438
4 4 0.7 11 16.4 532
4 6 0.7 12.3 18.7 764
4 10 0.7 14.5 21.1 1013
4 16 0.7 17 23.4 1360
4 25 0.9 21 26.1 2160
4 35 0.9 23.6 28.6 2690
4 50 1 25 32 3130
4 70 1.1 29.5 37.7 4500
4 95 1.1 33.3 41.7 5600
4 120 1.2 37.5 47.1 7400
4 150 1.4 41.6 51.4 8780
4 185 1.6 46.4 56.6 10630
4 240 1.7 52.6 63 13390
4 300 1.8 58 68.8 16290
4 400 2 65.4 78.1 19800
5 1.5 0.6 9.7 14.3 410
5 2.5 0.7 11.7 16.1 470
5 4 0.7 13 17.8 710
5 6 0.7 14.5 20 876
5 10 0.7 17.2 22.9 1165
5 16 0.7 20 26.6 1742
5 25 0.9 24.7 31.5 2323
5 35 0.9 27.8 34.8 2932
5 50 1 32.4 40.4 4192
7 1.5 0.6 10.2 15.2 470
7 2.5 0.7 12.3 17.1 600
7 4 0.7 13.6 19.1 881
12 1.5 0.6 13.7 19.4 780
12 2.5 0.7 16.3 22.4 1000
19 1.5 0.6 16.2 22.2 1000
19 2.5 0.7 19.9 26.6 1540
27 1.5 0.6 20 26.7 1500
27 2.5 0.7 24 30.7 1950
37 1.5 0.6 22.3 29 1800
37 2.5 0.7 26.9 33.8 2350

Class 2 Stranded Conductors for Single Core and Multi-Core Cables
Nominal Cross 
Sectional Area
Minimum No. Of Wires In Conductor Maximum Resistance 
of Conductor At 20ºC
mm² Circular Circular Compacted Shaped Annealed Copper Conductor
Cu Al Cu Al Cu Al Plain Wires ohms/km
1.5 7 - 6 - - - 12.1
2.5 7 - 6 - - - 7.41
4 7 - 6 - - - 4.61
6 7 - 6 - - - 3.08
10 7 7 6 6 - - 1.83
16 7 7 6 6 - - 1.15
25 7 7 6 6 6 6 0.727
35 7 7 6 6 6 6 0.524
50 19 19 6 6 6 6 0.387
70 19 19 12 12 12 12 0.268
95 19 19 15 15 15 15 0.193
120 37 37 18 15 18 15 0.153
150 37 37 18 15 18 15 0.124
185 37 37 30 30 30 30 0.0991
240 37 37 34 30 34 30 0.0754

BS 6724 LSZH Sheath 0.6/1kv LV Power Swa Armored Cable

4.2 BS 5467 SWA PVC 0.6/1kV Cable
4.2.1 Cable Construction:
Conductor Class 2 stranded copper conductor according to BS EN 60228
Insulation XLPE (Cross-Linked Polyethylene)
Bedding PVC (Polyvinyl Chloride)
Armour SWA (Steel Wire Armour)
Sheath PVC (Polyvinyl Chloride)

4.2.2 Electrical Characteristics
Dimensions - BS5467 XLPE/PVC/AWA/PVC (Copper)
No. of Cores Nominal Cross Sectional Area Nominal Thickness of Insulation Nominal Overall Diameter mm Nominal Weight
mm² mm Under Armour Overall kg/km
2 1.5 0.6 7.3 12.1 302
2 2.5 0.7 8.5 13.6 346
2 4 0.7 9.4 14.7 410
2 6 0.7 10.5 15.9 499
2 10 0.7 12.3 18 648
2 16 0.7 14.3 20.4 978
2 25 0.9 14.7 20.4 1290
2 35 0.9 16.8 23.3 1500
2 50 1 19 25.8 1890
2 70 1.1 22 29 2450
2 95 1.1 25.1 33.1 3300
2 120 1.2 27.9 36.1 4020
2 150 1.4 30.9 39.3 4750
3 1,5 0.6 7.8 12.6 330
3 2.5 0.7 9.2 14.1 390
3 4 0.7 10 15.3 464
3 6 0.7 11.2 16.6 568
3 10 0.7 13.1 19.5 866
3 16 0.7 15.3 21.6 1152
3 25 0.9 18.9 23.6 1800
3 35 0.9 21.3 25.7 2230
3 50 1 21.7 28.5 2490
3 70 1.1 25.2 32.2 3290
3 95 1.1 28.8 37 4440
3 120 1.2 32 40.4 5470
3 150 1.4 35.9 45.5 6930
3 185 1.6 40 49.8 8350
3 240 1.7 44.9 55.1 10400
3 300 1.8 49.8 60.2 12600
3 400 2 55.8 66.6 14600
4 1.5 0.6 8.5 13.3 365
4 2.5 0.7 9.9 15 438
4 4 0.7 11 16.4 532
4 6 0.7 12.3 18.7 764
4 10 0.7 14.5 21.1 1013
4 16 0.7 17 23.4 1360
4 25 0.9 21 26.1 2160
4 35 0.9 23.6 28.6 2690
4 50 1 25 32 3130
4 70 1.1 29.5 37.7 4500
4 95 1.1 33.3 41.7 5600
4 120 1.2 37.5 47.1 7400
4 150 1.4 41.6 51.4 8780
4 185 1.6 46.4 56.6 10630
4 240 1.7 52.6 63 13390
4 300 1.8 58 68.8 16290
4 400 2 65.4 78.1 19800
5 1.5 0.6 9.7 14.3 410
5 2.5 0.7 11.7 16.1 470
5 4 0.7 13 17.8 710
5 6 0.7 14.5 20 876
5 10 0.7 17.2 22.9 1165
5 16 0.7 20 26.6 1742
5 25 0.9 24.7 31.5 2323
5 35 0.9 27.8 34.8 2932
5 50 1 32.4 40.4 4192
7 1.5 0.6 10.2 15.2 470
7 2.5 0.7 12.3 17.1 600
7 4 0.7 13.6 19.1 881
12 1.5 0.6 13.7 19.4 780
12 2.5 0.7 16.3 22.4 1000
19 1.5 0.6 16.2 22.2 1000
19 2.5 0.7 19.9 26.6 1540
27 1.5 0.6 20 26.7 1500
27 2.5 0.7 24 30.7 1950
37 1.5 0.6 22.3 29 1800
37 2.5 0.7 26.9 33.8 2350

Class 2 Stranded Conductors for Single Core and Multi-Core Cables
Nominal Cross 
Sectional Area
Minimum No. Of Wires In Conductor Maximum Resistance 
of Conductor At 20ºC
mm² Circular Circular Compacted Shaped Annealed Copper Conductor
Cu Al Cu Al Cu Al Plain Wires ohms/km
1.5 7 - 6 - - - 12.1
2.5 7 - 6 - - - 7.41
4 7 - 6 - - - 4.61
6 7 - 6 - - - 3.08
10 7 7 6 6 - - 1.83
16 7 7 6 6 - - 1.15
25 7 7 6 6 6 6 0.727
35 7 7 6 6 6 6 0.524
50 19 19 6 6 6 6 0.387
70 19 19 12 12 12 12 0.268
95 19 19 15 15 15 15 0.193
120 37 37 18 15 18 15 0.153
150 37 37 18 15 18 15 0.124
185 37 37 30 30 30 30 0.0991
240 37 37 34 30 34 30 0.0754
300 61 61 34 30 34 30 0.0601
400 61 61 53 53 53 53 0.047
Notes
1. Where a conductor operates at a temperature exceeding 70ºC it must be ascertained that the equipment connected to the conductor is suitable for the conductor operating temperature.
2. Where cables in this table are connected to equipment or accessories designed to operate at a temperature not exceeding 70ºC , the current ratings given in the equivalent table for 70ºC thermoplastic insulated cables must be used.

For more information, don't hesitate to call us on +86-15838290725 or send inquiry to me.
BS 6724 LSZH Sheath 0.6/1kv LV Power Swa Armored Cable
BS 6724 LSZH Sheath 0.6/1kv LV Power Swa Armored Cable BS 6724 SWA Armoured LSZH Sheath 0.6/1kV LV Power Armour Cable

1. Overview
Low Voltage Power Cables, Aluminum and Copper conductors of voltage range:0.6/1.0 kV.

2. Cable Types
Copper Conductor Cables
Aluminium Conductor Cables
Thermoplastic/ PVC Insulated Cables
Thermoset/XLPE Insulated Cables
Armoured/ Non - Armoured Cables
Single core cables up to and including 1000 mm2
2 core cables up to and including 95 mm2
3, 4 core & 4 core with reduced neutral cables up to and including 500 mm2

3. Applicable Standards
IEC 60502 (Part 1)"PVC/ XLPE insulated cables" single core /multi-core BS 5467 for XLPE insulated Armoured cables
BS 7889 for XLPE insulated single core unarmoured cables
BS 6724 LSZH Sheath 0.6/1kv LV Power Swa Armored Cable

4. Cables Include:
4.1 BS 6724 SWA LSZH 0.6/1kV Cable
4.1.1 Cable construction
Conductor Class 2 stranded copper conductor according to BS EN 60228
Insulation XLPE (Cross-Linked Polyethylene)
Bedding LSZH (Low Smoke Zero Halogen) Type LTS1 according to BS 7655
Armour SWA (Steel Wire Armour)
Sheath LSZH (Low Smoke Zero Halogen) Type LTS1 according to BS 7655

4.1.2 Electrical Characteristics
Dimensions - BS6724 XLPE/LSZH/SWA/LSZH (Copper)
No. of Cores Nominal Cross Sectional Area Nominal Thickness of Insulation Nominal Overall Diameter mm Nominal Weight
mm² mm Under Armour Overall kg/km
2 1.5 0.6 7.3 12.1 302
2 2.5 0.7 8.5 13.6 346
2 4 0.7 9.4 14.7 410
2 6 0.7 10.5 15.9 499
2 10 0.7 12.3 18 648
2 16 0.7 14.3 20.4 978
2 25 0.9 14.7 20.4 1290
2 35 0.9 16.8 23.3 1500
2 50 1 19 25.8 1890
2 70 1.1 22 29 2450
2 95 1.1 25.1 33.1 3300
2 120 1.2 27.9 36.1 4020
2 150 1.4 30.9 39.3 4750
3 1,5 0.6 7.8 12.6 330
3 2.5 0.7 9.2 14.1 390
3 4 0.7 10 15.3 464
3 6 0.7 11.2 16.6 568
3 10 0.7 13.1 19.5 866
3 16 0.7 15.3 21.6 1152
3 25 0.9 18.9 23.6 1800
3 35 0.9 21.3 25.7 2230
3 50 1 21.7 28.5 2490
3 70 1.1 25.2 32.2 3290
3 95 1.1 28.8 37 4440
3 120 1.2 32 40.4 5470
3 150 1.4 35.9 45.5 6930
3 185 1.6 40 49.8 8350
3 240 1.7 44.9 55.1 10400
3 300 1.8 49.8 60.2 12600
3 400 2 55.8 66.6 14600
4 1.5 0.6 8.5 13.3 365
4 2.5 0.7 9.9 15 438
4 4 0.7 11 16.4 532
4 6 0.7 12.3 18.7 764
4 10 0.7 14.5 21.1 1013
4 16 0.7 17 23.4 1360
4 25 0.9 21 26.1 2160
4 35 0.9 23.6 28.6 2690
4 50 1 25 32 3130
4 70 1.1 29.5 37.7 4500
4 95 1.1 33.3 41.7 5600
4 120 1.2 37.5 47.1 7400
4 150 1.4 41.6 51.4 8780
4 185 1.6 46.4 56.6 10630
4 240 1

A Power Cable is a electrical cable applied for transmission and distribution of electrical power. It is an assembly of single or multiple copper or aluminum conductors covered by PVC or XLPE insulation, and usually held together with an overall PVC sheath by cabling process. For high flexibility and excellent mechanical protection,it can also be armored by steel tape or wire. Our power cables can also be classified by current as for AC and DC system.

      

Our power cable type classified by voltage

  •      Low Voltage
  •      Medium Voltage
  •      High Voltage

Our power cable type classified by insulation

  •      PVC Insulated & Sheathed  
  •      XLPE Insulated PVC Sheathed  
  •      PE Insulated &Sheathed Flame Retardant
  •      Metal Shielded  
  •      Low smoke halogen Free Flame Retardant/Fire Retardant
  •      Aluminum Stranded Conductor (AAC )

Main Advantage

  1.        Economic space occupation
  2.        For laying indoors, tunnels or pipe. Less wire insulation distance,no need to build an grounding tower.
  3.        High reliability
  4.        Less impacted by climate and surround environment,steady transmission performance.
  5.        Less distributed capacitance &maintenance effort & electrical-shock possibility

 low volatge electrical power cables

power cables with PVC insulation and sheath

Application

1.Power cables may be installed as permanent wiring within buildings, buried in the ground, run overhead, or exposed.

2. Flexible power cables are used for portable devices, mobile tools and machinery.


Please do not hesitate to contact us if you have any questions about electrical power cables. OEM service is also available based on official authorization.

Power Cable

Power Cable,Aluminum Power Cable,Insulated Power Cable,Armoured Power Cable

Fujian Lien Technology Co.,Ltd , http://www.liencable.com

This entry was posted in on