0.6kv/11kv/22kv/35kv XLPE Insulated Overhead Service Drop Cable ABC Cable

Model NO.: ABC Cable
Certification: ISO, CCC, BV, SGS
Brand: Rmjt
Product Name: 0.6kv/11kv/22kv/35kv XLPE Insulated Overhead Servi
OEM: Yes
Standard: IEC, BS, DIN, ASTM, NFC
Manufacturer: People′s Cable Group
Voltage Type: Low Voltage, Medium Voltage
Sample: Free
Rated Voltage: 0.6/1kv, 11kv, 22kv, 35kv
Core: Single/Duplex / Triplex/ Quadruplex
Trademark: RMjT
Transport Package: Standard Export Wooden Reel or Coil
Specification: 10-150mm2
Origin: Henan, China
HS Code: 8544492100
Model NO.: ABC Cable
Certification: ISO, CCC, BV, SGS
Brand: Rmjt
Product Name: 0.6kv/11kv/22kv/35kv XLPE Insulated Overhead Servi
OEM: Yes
Standard: IEC, BS, DIN, ASTM, NFC
Manufacturer: People′s Cable Group
Voltage Type: Low Voltage, Medium Voltage
Sample: Free
Rated Voltage: 0.6/1kv, 11kv, 22kv, 35kv
Core: Single/Duplex / Triplex/ Quadruplex
Trademark: RMjT
Transport Package: Standard Export Wooden Reel or Coil
Specification: 10-150mm2
Origin: Henan, China
HS Code: 8544492100

0.6kv/11kv/22kv/35kv XLPE Insulated Overhead Service Drop Cable ABC Cable

Application
a. Duplex Service Drop
Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum.
b. Triplex Service Drop
Application: To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene   insulation 90°C maximum for crosslinked insulation.
c. Quadruplex Service Drop.
Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at  conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors.


Constructions
Conductor: Round, stranded and compacted aluminum conductor
Insulation: HDPE, XLPE, PVC
3 power cores consisting of standard aluminium conductors, insulated withXLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.
To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crossliked polyethylene(XLPE) insulated conductors.

Standard
GB12527-91,IEC502, BS7870-5,NFC33-209
Other standards such as BS,DIN,ASTM and ICEA upon request

Specifications
Phase Phase Phase Approx.Overall Diameter

 
Max. D.C. Resistance of Conductor at 20ºC

 
AAC+XLPE Compact Conductor XLPE Insulation
No. X Normal Cross Section of Cores No.of Al Wires Overall Diameter Normal Thickness Min. Diameter
No. X mm2 - mm mm mm mm mm ohm/km
1 X 10 7 4.05 1 0.8 6.05 6.05 3.08
1 X 16 7 4.8 1.2 0.98 7.2 7.2 1.91
1 X 25 7 6 1.2 0.98 8.4 8.4 1.2
1 X 35 7 7 1.4 1.16 9.8 9.8 0.868
1 X 50 7 8.3 1.4 1.16 11.1 11.1 0.641
1 X 70 19 9.8 1.4 1.16 12.6 12.6 0.443
1 X 95 19 11.6 1.6 1.34 14.8 14.8 0.32
1 X 120 19 13 1.6 1.34 16.2 16.2 0.253
1 X 150 19 14.6 1.8 1.52 18.2 18.2 0.206
1 X 185 36 16.2 2 1.7 20.2 20.2 0.164
1 X 240 36 18.4 2.2 1.88 22.8 22.8 0.125
2 X 10 7 4.05 1 0.8 6.05 12.1 3.08
2 X 16 7 4.8 1.2 0.98 7.2 14.4 1.91
2 X 25 7 6 1.2 0.98 8.4 16.8 1.2
2 X 35 7 7 1.4 1.16 9.8 19.6 0.868
2 X 50 7 8.3 1.4 1.16 11.1 22.2 0.641
2 X 70 19 9.8 1.4 1.16 12.6 25.2 0.443
2 X 95 19 11.6 1.6 1.34 14.8 29.6 0.32
2 X 120 19 13 1.6 1.34 16.2 32.4 0.253
2 X 150 19 14.6 1.8 1.52 18.2 36.4 0.206
2 X 185 36 16.2 2 1.7 20.2 40.4 0.164
2 X 240 36 18.4 2.2 1.88 22.8 45.6 0.125
3 X 10 7 4.05 1 0.8 6.05 13.07 3.08
3 X 16 7 4.8 1.2 0.98 7.2 15.55 1.91
3 X 25 7 6 1.2 0.98 8.4 18.14 1.2
3 X 35 7 7 1.4 1.16 9.8 21.17 0.868
3 X 50 7 8.3 1.4 1.16 11.1 23.98 0.641
3 X 70 19 9.8 1.4 1.16 12.6 27.22 0.443
3 X 95 19 11.6 1.6 1.34 14.8 31.97 0.32
3 X 120 19 13 1.6 1.34 16.2 34.99 0.253
3 X 150 19 14.6 1.8 1.52 18.2 39.31 0.206
3 X 185 36 16.2 2 1.7 20.2 43.63 0.164
3 X 240 36 18.4 2.2 1.88 22.8 49.25 0.125
4 X 10 7 4.05 1 0.8 6.05 14.64 3.08
4 X 16 7 4.8 1.2 0.98 7.2 17.42 1.91
4 X 25 7 6 1.2 0.98 8.4 20.33 1.2
4 X 35 7 7 1.4 1.16 9.8 23.72 0.868
4 X 50 7 8.3 1.4 1.16 11.1 26.86 0.641
4 X 70 19 9.8 1.4 1.16 12.6 30.49 0.443
4 X 95 19 11.6 1.6 1.34 14.8 35.82 0.32
4 X 120 19 13 1.6 1.34 16.2 39.2 0.253
4 X 150 19 14.6 1.8 1.52 18.2 44.04 0.206
4 X 185 36 16.2 2 1.7 20.2 48.88 0.164
4 X 240 36 18.4 2.2 1.88 22.8 55.18 0.125
 
1.

motor wiring board

Dk Phase Motor Centrifugal Pump,A2 Phase Motor.Driver,Split Phase Motor A2,Motor Control Board

Ningbo Zhenhai Rongda Electrical Appliance Co., Ltd. , https://www.centrifugalswitch.com

This entry was posted in on