Hitachi elevator TD3100 inverter parameter setting

Function keyboard faceplate display unit setting value

Code name

F0.01 Language selection language selection 1 0

F0.02 Operation mode Select operation mode 1 2

F0.03 Running speed digital setting running speed setting 0.001m/s 0

F0.04 Running direction switching direction of operation 1 0

F0.05 Elevator rated speed rated speed 0.001m/s 60 90 105

1 1.5

F0.06 Maximum output frequency Maximum frequency 0.01Hz 50

F0.07 carrier frequency adjustment carrier frequency 0.1kHz 7

F0.08 Parameter update parameter update 1 0

F1.00 PG pulse number selection PG pulse number 1 1024

F1.01 Motor type selection motor type selection 1 0

F1.02 Motor power rated power 0.1KW 7.5KW 11KW 15KW 18.5KW

F1.03 Motor rated voltage rated voltage 1V 360V

F1.04 Motor rated current rated current 0.1A 27.5

F1.05 Motor rated frequency rated frequency 0.01Hz 50

F1.06 Motor rated speed rated speed 1r/min 960

F1.08 Motor overload protection mode select overload protection 1 1 or 2

F1.10 Motor automatic tuning protection automatic tuning protection 1 0

F1.12 Stator resistance stator resistance 0.001 ohm 0.338 0.307

F1.13 Stator inductance stator inductance 0.1mH 85 55.3

F1.14 Rotor resistance rotor resistance 0.001 ohm 0.367 0.346

F1.15 Rotor Inductor Rotor Inductance 0.1mH 54.9 55.3

F1.16 Mutual inductance mutual inductance 0.1mH 54.9 52.4

F1.17 No-load excitation current no-load excitation current 0.1A 9 11.7

F2.00 ARS proportional gain 1 ASR1-P 0 1

F2.01 ARS integration time 1 ASR1-1 0.001s 1

F2.02 ARS proportional gain 2 ASR2-P 0 2

F2.03 ARS integration time 2 ASR2-1 0.001s 0.5

F3.06 Multi-end speed 3 Multi-end speed 3 0.001m/s 0.04

F3.07 multi-end speed 4 multi-end speed 4 0.001m / s 0.25

F3.08 Multi-end speed 5 Multi-end speed 5 0.001m/s 1

F3.09 Multi-terminal speed 6 Multi-end speed 6 0.001m/s 1

F3.10 Multi-speed 7 Multi-end speed 7 0.001m/s 60 90 105

1 1.5

F5.05 Ordinary digital input X6 sub-function selection X6 sub-function 1 8

F5.06 Ordinary digital input X7 sub-function selection X7 sub-function 1 9

F5.07 Ordinary digital input X8 sub-function selection X8 sub-function 1 10

F5.30 Open collector output Y1 function selection Y1 function selection 1 14

F5.31 Open collector output Y2 function selection Y2 function selection 1 0

F5.32 Open collector output Y3 function selection Y3 function selection 1 1

F5.35 Y1~Y4, PR action mode selection action mode selection 1 01

F7.03 Programmer crossover output division factor 1 4

F9.01 LED operation display parameter selection 2 Operation display 2 (not flashing) 1 255

F9.02 LED stop display parameter (flashing) Stop display 1 13