**Introduction to Current Transformers**
A current transformer (CT) is an electrical device that converts a large current on the primary side into a smaller, proportional current on the secondary side using the principle of electromagnetic induction. It consists of a closed core and two windings: a primary winding with fewer turns and a secondary winding with more turns. The primary winding is connected in series with the circuit where the current needs to be measured, allowing it to carry the full current of the line.
The secondary winding is connected in series with measuring instruments or protection circuits. During operation, the secondary circuit remains closed, ensuring that the impedance of the connected devices is low, which keeps the CT operating close to a short-circuit condition. This design prevents the secondary from being open, as doing so could result in dangerously high voltages. The CT's main purpose is to safely isolate and scale down high currents for measurement and protection purposes, making it an essential component in power systems.
**Structural Composition of a Current Transformer**
A current transformer is made up of several key components: a primary coil, a secondary coil, a magnetic core, insulation support, and terminal points. The core is typically constructed from laminated silicon steel sheets to reduce eddy current losses. The primary winding is connected in series with the main circuit, and when current flows through it, it induces an alternating magnetic flux in the core. This flux then induces a corresponding current in the secondary winding.
Assuming negligible excitation losses, the relationship between the primary and secondary currents follows the equation I1N1 = I2N2, where N1 and N2 are the number of turns in the primary and secondary coils, respectively. The current transformation ratio, K, is defined as K = I1/I2 = N2/N1. The primary winding must be insulated to match the voltage of the main circuit to ensure safety for both the secondary circuit and personnel. The secondary circuit includes meters, relays, and other protective devices, and CTs can be categorized into those used for measurement and those used for protection.
**Current Transformer Working Principle**
The working principle of a current transformer is based on Faraday’s law of electromagnetic induction. When the primary current flows through the primary winding, it generates a magnetic flux in the core, which induces a secondary current in the secondary winding. The secondary circuit is always closed to prevent open-circuit conditions that could lead to dangerous voltage spikes.
In an ideal CT, assuming no magnetizing current (I0 = 0), the magnetomotive forces of the primary and secondary windings are equal and opposite, resulting in the equation I1N1 = -I2N2. This indicates that the primary and secondary currents are inversely proportional to their respective number of turns. The current ratio, K = I1/I2, allows the primary current to be calculated from the known secondary current. Additionally, the secondary current phasor is 180° out of phase with the primary current, a characteristic known as polarity reduction.
**Main Parameters of a Current Transformer**
1. **Rated Current Ratio**
The rated current ratio is the ratio of the primary rated current to the secondary rated current. For example, if the primary current is 100 A and the secondary is 5 A, the ratio is 100/5. This ratio determines how much the current is scaled down for safe measurement and protection.
2. **Accuracy Class**
Accuracy classes define the maximum permissible error in the CT’s output. Common classes include 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1.0, 3.0, 5.0, 0.2S, and 0.5S. Higher accuracy classes are used in precision applications like laboratory measurements, while lower classes are suitable for general metering and protection.
3. **Rated Capacity**
The rated capacity refers to the apparent power (in VA) that the CT can supply at its rated secondary current. It is calculated as S2e = I2e² × Z2e. Ensuring that the total impedance of the connected devices does not exceed this value is crucial for maintaining accuracy.
4. **Rated Voltage**
The rated voltage specifies the maximum voltage the primary winding can withstand without damage. It reflects the insulation strength of the CT and is usually marked on the device’s nameplate.
5. **Polarity Marking**
Polarity markings (L1, L2, K1, K2) indicate the direction of current flow. Proper wiring ensures that the secondary current flows in the correct direction relative to the primary, which is essential for accurate measurement and protection.
**Role of Current Transformers**
1. **Measurement Function**
Current transformers are widely used for measuring large AC currents. They convert high currents into manageable levels for meters, ensuring safety and accuracy. This also provides electrical isolation, reducing the risk of direct contact with high-voltage lines.
2. **Protection Function**
In protection systems, CTs work with relays to detect faults such as overloads or short circuits. When abnormal currents are detected, the relay triggers a trip to isolate the faulty section, protecting the power system from damage. Protection CTs are designed to handle high currents and maintain accuracy under fault conditions.
Overall, current transformers play a vital role in modern power systems by enabling safe, accurate, and reliable monitoring and protection of electrical circuits.