Industrial power transformer model specifications and components

Power transformer specification

The standard power supply voltage rating is: 400 (380) V, 3000 V, 6300 V, 35000 V, 10000 V, 110000 V, 220000 V.

Therefore, the transformer has 6300/400; 10000/400; 35000/6300; 220000/10000 and other various ratios. There are also three turns of transformers such as 220000/35000/6300

Among them, 3000V, 6300V, and 110000V are transitional industrial electrical voltages, which are rare for civilian use.

Now 500,000 volts of ultra-high voltage DC power supply has been added.

Industrial transformers are available in several sizes

Industrial power transformer model specifications and components

Classification of industrial transformers: 1. According to the number of phases

1) Single-phase transformer: for single-phase load and three-phase transformer group.

2) Three-phase transformer: used for the rise and fall voltage of three-phase systems.

2, according to the cooling method

1) Dry-type transformer: relying on air convection for natural cooling or increasing fan cooling, it is mostly used for small-capacity transformers such as high-rise buildings, high-speed toll stations, local lighting, and electronic circuits.

2) Oil-immersed transformer: rely on oil as cooling medium, such as oil-immersed self-cooling, oil-immersed air-cooled, oil-immersed water-cooled, forced oil circulation, etc.

3, according to the purpose of 1) power transformer: for the transmission and distribution system of the rise and fall voltage.

2) Instrument transformers: such as voltage transformers, current transformers, measuring instruments and relay protection devices.

3) Test transformer: It can generate high voltage and carry out high voltage test on electrical equipment.

4) Special transformers: such as electric furnace transformers, rectifier transformers, regulating transformers, capacitive transformers, phase shifting transformers, etc.

4, according to the form of winding

1) Two-winding transformer: used to connect two voltage levels in the power system.

2) Three-winding transformer: Generally used in power system regional substation, connecting three voltage levels.

3) Autotransformer: A power system used to connect different voltages. Can also be used as a normal boost or post-down transformer.

5, according to the core form

1) Core transformer: Power transformer for high voltage.

2) Amorphous alloy transformer: Amorphous alloy core transformer is a new type of magnetic conductive material, the no-load current is reduced by about 80%, which is an ideal distribution transformer for energy saving, especially suitable for rural power grids and developing regions. Lower place.

3) Shell-type transformer: special transformer for high current, such as electric furnace transformer, electric welding transformer; or power transformer for electronic equipment and television, radio, etc.

Power transformer parts

The power transformer is mainly composed of the following components: the body, the fuel tank, the oil pillow, the casing, the radiator and the like. The body is composed of a core and a coil, and the coil includes a primary coil and a secondary coil. The fuel tank is equipped with an explosion-proof cylinder (pressure release), a respirator, a gas relay, a thermometer, and the like.

Fine pitch Indoor LED Module

Short Description:P2mm Indoor LED Module,256mmx128mm P2mm Indoor LED Panel with 128x64 pixels. Model:ERALED-P2-Indoor-128X64; 5 Years Warranty with NICHIA/CREE/NATIONSTAR/EPISTAR/SILAN gold wires LED lamps,1.6cm thickness PCB,MBI5153 Driving IC ;UL,CE,RoHS,FCC,3C,ISO Approved;


Fine pitch Indoor LED Module

256x128mm,128x64 pixels RGB full color SMD UHD P2mm Indoor LED display Module

Module Specifications

1

Pixel Pitch

2mm

2

Pixel Configuration

SMD3in1

3

Module Resolution

128x64 pixels

4

Module Pixles

25,000 pixels

5

Module Size

256x128mm

Specifications

1

Screen Brightness

≥1000cd/m2

2

Driving Method

1/32 scan

3

Mini Viewing Distance

2m

4

Max. Power Consumption

750W/m2

5

Average Power Consumption

320W/m2

6

Gray Level

14bits input, 4096 levels(212)

7

Display Color

16M

8

Frame Frequency

≥60Hz

9

Refresh Frequency

≥1920Hz

10

Uninterrupted Working Hours

≥72 hours

11

Screen Life-span

≥100,000 hours

12

MTBF

≥5,000 hours

13

Discrete Blind Spot Rate

<1/10000

14

Continuous Blind Spot Rate

None

15

Blind Spot Rate

<1/10000

16

Screen Plainness

<±1mm

17

Power Supply Mode

AC220±10% 50Hz/AC110±10% 60Hz

18

Environment Temperature & Humidity

Temperature:-20 Celsius~+60 Celsius
Humidity:10%~90% RH

19

Control Mode

Synchronous display with control PC by DVI

20

Control System

DVI video card + full color control card + fiber system( optional)

21

Display Content

Video, DVD, VCD, TV, picture, cartoon, graphics, texts.etc.

22

Interface

Standard Ethernet

23

Transmission Distance

Multi mode fiber <500m, single mode fiber <30km,internet cable <100m

Fine pitch Indoor LED Module


High Power Led Module,Soft Flexible Led Display Screen,Pitch Led Display Screen,Curved Led Display Screen

Shenzhen Joy LED Display Co., Ltd. , https://www.joe-led.com

This entry was posted in on